Sign In | Join Free | My brakesband.com
brakesband.com
Products
Search by Category
Home > General Mechanical Components Design Services >

Electric Pneumatic Slide Gate Dampers For Boilers Flue Air Ducts And Pulverized Coal Pipe

Categories Slide Gate Dampers
Brand Name: FIDAK
Model Number: NIL
Certification: ISO9001
Place of Origin: China
MOQ: 10 pieces
Price: Negotiable
Payment Terms: T/T, Western Union,Paypal
Supply Ability: 40 tons per day
Delivery Time: 5~15 working days
Packaging Details: Steel frame case sealed by plywoods with each end capped
Product name: Slide Damper Gate Valve
Material: Carbon Steel
Color: Customer′s Request
Actuator: Manual,Electric,Pneumatic
Nominal Pressure: ≤30Kpa
Application: For boilers, hot and cold air ducts, flue air ducts and pulverized coal pipelines
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Electric Pneumatic Slide Gate Dampers For Boilers Flue Air Ducts And Pulverized Coal Pipe

    Electric Manual Pneumatic Slide Gate Damper For boilers flue air ducts and pulverized coal pipe


    Product description


    The slide gate damper is an important auxiliary equipment for the boiler. It is installed in the occasions where the cold and hot air ducts of the thermal power plant boilers need to be shut off and isolated, such as the inlet and outlet ducts of coal mills. The product is reliable, flexible to open and close, and tightly sealed, which fundamentally solves the disadvantages of the previous isolation door that is not tightly closed and the closing time is too long, which greatly facilitates the switching and decommissioning of equipment,Power plant.


    Classification of sliding door


    Electric sliding door, manual sliding door, pneumatic sliding door.

    Manual plug-in door is also called manual screw gate valve. Most of them are used for unloading device. There are two types: square mouth and round mouth. The manual plug-in valve is durable, has small flow resistance, small size, light weight, convenient maintenance, and is widely used.

    Pneumatic sliding door is a main control device for the flow or conveyance of powder, grain, granules and small pieces of material. It is widely used in metallurgy, mining, building materials, food, chemical and other industries to control the flow change or quickly cut off the flow. .

    There is a round port with a diameter on the gate plate of the electric plug-in door. The opening and closing of the gate plate makes the round port on the gate plate completely separate from and match the path.


    Technical Parameters


    1. Model: A (length) * B (width) * H (height)
    Note: A * B can be a variety of air ducts such as rectangles and circles, which are determined by the user. H damper thickness is generally 560mm.
    2. Medium: dusty particles, coal ash.
    3. Design temperature: ≤1000 ℃.
    4. Withstand pressure: ≤30Kpa.
    5, interface material;
    The technical parameters of this product can be customized according to the special requirements of users. "


    Features


    1. The slide gate damper is an indispensable device for the safe operation system of the power plant boiler. Compared with similar products, it has a simple structure, good tightness and high temperature resistance. Abrasion resistance and other advantages, fast opening and closing speed, convenient operation, safe and reliable operation, easy maintenance and repair.


    2. The slide gate damper is installed vertically or horizontally on the pulverized coal pipeline at the entrance of the combustion chamber, and the door plate is moved in the door frame by a driving device to cut off the pulverized coal mixed gas between the coal mill and the combustion chamber (boiler), and Ensure that the combustion chamber flame does not enter the pulverized coal pipeline.


    Application


    1. The slide gate damper adopts a new design in structure. The door is made convex and has a groove at the top for high sealing. The door is made of stainless steel and has high temperature and corrosion resistance. A high temperature resistant silicone rubber is installed between the upper and lower door frames, and the degree of sealing can be controlled by adjusting the tightness.


    2. The slide gate damper is installed vertically or horizontally on the pulverized coal pipeline at the entrance of the combustion chamber, and the door plate is moved in the door frame by a driving device to cut off the pulverized coal mixed gas between the coal mill and the combustion chamber (boiler), and Ensure that the combustion chamber flame does not enter the pulverized coal pipeline.