FMU30 E&H Instrument

Categories E&H Instrument
Brand Name: Endress+Hauser
Model Number: FMU30-AAHEABGHF
Certification: RoHs
Place of Origin: Germany
MOQ: 1
Price: Negotiable
Payment Terms: L/C, T/T
Supply Ability: 100+pc+weeks
Delivery Time: On request
Accuracy: +/- 3 mm or +/- 0.2 % of set measuring range
Accuracy +/- 3 mm or +/- 0.2 % of set measuring range Process temperature: -20 °C ... 60 °C (-4 °F ... 140 °F)
Process pressure absolute / max. overpressure limit: 0.7 bar ... 3 bar abs (10 psi ... 44 psi)
Max. measurement distance: Sensor 1-1/2": 2 m (6.6 ft) Sensor 2": 3.5 m (11 ft)
Main wetted parts: PP/EPDM
Model: FMU30-AAHEABGHF
Manufacturer: Endress+Hauser
Origin: Germany
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    FMU30 E&H Instrument


    Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FMU30-AAHEABGHF


    Description:


    Manufacturer : Endress+Hauser

    Product No. : FMU30-AAHEABGHF

    Product type : Prosonic T FMU30 Ultrasonic measurement Time-of-Flight Prosonic

    AA - Approval : Non-hazardous area

    H - Display Operating : Envelope curve display on site; push button

    E - Electrical COnnection : Gland M20, IP68

    AB - Sensor; Max range; Blocking Distance : 2"; 8m liquid/3.5m solid; 0.35m

    GHF - Process connection : Thread ISO228 G2, PP

    Ambient temperature : -20 °C to +60 °C (-4 °F to 140 °F)

    Storage temperature : -40 °C to +80 °C (-40 °F to 176 °F)

    Weight : 0.8 Kg

    Shipping weight : 2 Kg


    Additional Informaiton:


    The range of applications extends from monitoring levels in sewage treatment plants and process water tanks to applications for loading, storage and buffer tanks. FMU30 ultrasonic sensor offers proven software algorithms and all warning and alarm messages are shown on the four-line plain text display and guarantee fast remedy of problems. The envelope curve can also be shown on the display. As the analysis results are displayed directly on-site, this ensures quick and accurate error diagnostics.


    Specs at a glance


    Accuracy
    +/- 3 mm or +/- 0.2 % of set measuring range

    Process temperature
    -20 °C ... 60 °C
    (-4 °F ... 140 °F)

    Process pressure absolute / max. overpressure limit
    0.7 bar ... 3 bar abs
    (10 psi ... 44 psi)

    Max. measurement distance
    Sensor 1-1/2": 2 m (6.6 ft)
    Sensor 2": 3.5 m (11 ft)

    Main wetted parts
    PP/EPDM


    Benefits


    Quick and simple commissioning via menu-guided onsite operation with four-line plain text display, 7 languages selectable

    Envelope curves on the on-site display for simple diagnosis

    Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate

    Non-contact measurement method minimizes service requirements

    Installation possible from thread G 1½ or 1½ NPT upwards

    Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

    Show less


    Field of application



    Two-wire instrument for continuous non-contact level and flow measurement.

    Process connection: Thread

    Temperature: -20 to +60°C (-4 to +140°F)

    Pressure: +0.7 to +3bar (+10 to +44psi)

    Maximum measuring distance:
    Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft),
    Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft)

    Blocking distance:
    Sensor 1½" 0.25m (0.8ft),
    Sensor 2" 0.35m (1.15ft)

    International explosion protection certificates

    Show less


    Features and specifications



    Continuous / Solids
    Point Level / Solids
    Point Level / Liquids
    Continuous / Liquids
    Measuring principle
    Ultrasonic

    Characteristic / Application
    Compact ultrasonic transmitter

    Supply / Communication
    2-wire

    Accuracy
    +/- 3 mm or +/- 0.2 % of set measuring range

    Ambient temperature
    -20 °C ... 60 °C

    (-4 °F ... 140 °F)

    Process temperature
    -20 °C ... 60 °C

    (-4 °F ... 140 °F)

    Process pressure absolute / max. overpressure limit
    0.7 bar ... 3 bar abs

    (10 psi ... 44 psi)

    Main wetted parts
    PP/EPDM


    Process connection
    G / NPT 1 1/2"

    G / NPT 2"

    Blocking distance
    Sensor 1 1/2": 0.25 m

    Sensor 2": 0.35 m

    Max. measurement distance
    Sensor 1-1/2": 2 m (6.6 ft)

    Sensor 2": 3.5 m (11 ft)

    Communication
    4...20 mA

    Certificates / Approvals
    ATEX, CSA C/US, IEC Ex, NEPSI


    Options
    Accessory Enclosed:

    UNI flange 2" ... 4"

    Application limits
    Take notice of range diagram


    Common Models:


    FDU91-RG1AACPS76FMU90-R11CA131AA3APMC131
    FDU91-RG2AACPS96FMU90-R11CA212AA3APMP131
    FDU91-RG3AACPS42CM42-MEA000EAZ00PMD55
    FDU92-RG2ACPS72CM42-MAA000EAZ00PMD75
    FMU30-AAHEAAGGFCPS92FMU41-ARH2A2,0-5mFMD77
    FMU30-AAHEABGHFFTL20H-0TDJ2BFMU42-APB2A22AFTL20H
    FMU40-ARB2A2FTL20H-0TCJ2BXIFMU43-APG2A2FTL260
    FMU41-ARB2A2FTL20
    Buy FMU30 E&H Instrument at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Great System International Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0