Sign In | Join Free | My brakesband.com
brakesband.com
Products
Search by Category
Home >

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Categories DAF and Electrocoaggulation
Brand Name: Loren
Model Number: REF seris (1-50)
Certification: ISO
Place of Origin: CHINA
MOQ: 1
Payment Terms: T/T, Western Union, MoneyGram, , L/C
Supply Ability: 50 sets per month
Delivery Time: 30 days for containerized order
Packaging Details: poly or wooden box or as per demand
Color: Main Host can be customized
Electrode: Aluminium, Titanium , SS, iron etc optional as per water data
Design: Modules Design optional for power supply e-box, main host and electrode assembly sets
Cost of Invest and Run or Maintenance: cheaper for long time running ,only change electrode plates
More we can do: total EC solutin , or Total Waste water ZLD solution
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

      1. Ectrocoagulation, Electrooxidation , Electroperoxi-coagulation
      2. Fully Enclosed Circular Electrocoagulation & Electroflotation Dissolved Air Flotation Equipment

        Brief of EC or EF Tech and Method


    Electrocoaggulation or Electroflocculation Process can be used alone or in combination with other treatment methods to rapidly improve the biodegradability of Industrial wastewater such as refractory organic wastewater in pharmaceutical, chemical, fuel industry esp. for toxic substances , Heavy metal, emulsified organic matter excellent removal efficiency.

    Outstanding Characteristic and Feature

    1.Adapt to a Wide Range of Wastewater to Handle a Variety of Pollutants

    2.30-Year Applied Unique Special Electrodes Layout with No Blocking

    3.Electrodes Last for 100 to 250 days as per different Site Condition

    4.Low Investment Costs with High Volume Throughut

    5.Low Operating Costs

    6.Low Maintenance and Repair Costs

    7.No Need to add Any Chemicals

    8.Small Footprint

    9.Simple Operation and High Degree Of Automation

    10.Short Processing Time and High Processing Efficiency

    11.Equipment Processing Produces Less Sludge And Sludge


    Applicant

    1. High Concentration Organic Wastewater


    2. High Ammonia Nitrogen Wastewater


    3.Electroplating Wastewater (Including Heavy Metals)


    4. Fluorine- Containing Wastewater


    4. Dying and Printing (High Chroma) Wastewater Treatment

    6. Paper Mill Pretreament

    7.Shipyard Waste Water

    8.Oily Water Treatment

    9.Agriculture Breeding Waste Water

    10.Aquaculture Pig Farm Waste Water Pretreatment

    11.Electrolytic Manganese Wastewater

    12. Emulsified Liquid Waste Water Pretreatment


    13. Landfill Leachate Waste Water Disposal

    14. Integrated Waste Water Pretreatment

    15.Circuit Board Wastewater

    16. Rare Earth Materials Processing Waste Water

    17. Aquarium One Year No Changing Water Solution

    Fully Radical Electrocoaggulation System Reference Parameter Table

    ModelFlowPowerOutline Dimension (mm)Area (M2)Lifter
    Main HostPower CabinetAuto Float SlotMinimum
    REF-11.0m3/h4.5kWΦ450*1300600*400*1500Φ800*16005None
    REF-55.0m3/h15kWΦ820*2000800*600*1700Φ1400*2400180.5t
    REF-1010.0m3/h25kWΦ820*2300900*600*1800Φ1900*2400240.5t
    REF-3030.0m3/h60kWΦ1380*24001300*800*2200Φ2900*2800401.0t
    REF-5050.0m3/h90kWΦ1380*29001500*900*2500Φ4000*2800601.0t

    Equipment Operating Cost

    Electricity Consumption: 0.1-1.5kWh/ ton As per Different Waste Water

    Electrode Plate Loss: USDS 0.0014-0.0043 / M3 Water.

    Electric Flocculation Operation Cost: USDS 0.0086-0.1122/M3 Water. (Electricity Price Calculated as USDS 0.072 / kW)

    Installation Method

    The Electrocoagulation Machine can be installed at the location near the treatment site, and the power control cabinet should be placed in the drying equipment room. If there are special explosion-proof requirements, it needs to be explained in advance.

    Method of Operation

    The Electrofluculation Machine is a continuous automatic operation mode, and no special care is required. The water inlet is provided with a flow meter, and the flow rate can be controlled by the valve. The water is pressurized by the pump into other processing systems, or directly discharged, and the equipment discharge can be set to manual or automatic control according to requirements.

    Precautions

    1.When the Electrofluculation System is not in use, It cannot be energized to avoid danger and equipment damage.

    2.Do not arbitrarily power off when the equipment is working through water.

    3.Do not touch the voltage output when powering up to avoid danger.

    4.Keep the heat sink well ventilated when the device is powered.

    5.The electrical parts must not be watered or wrapped in plastic cloth or likewise.

    6.The Electrocoagulation equipment must be shut down before servicing.

    7. If the subsequent process or equipment has been fouled, the treated process or equipment should be drained once every 2 hours, no less than 3 minutes each time; and the dirt should be cleaned regularly to prevent the residue from clogging the equipment and causing an accident.


    8. Do not rub hard when loading or unloading equipment.

    Touch us freely

    Product Tags:

    water treatment systems

      
    Buy Fully Enclosed Circular  Electrocoagulation System  , Electrocoaggulation Electrolysis Machine , Air Flotation Machine , at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Loren Industry Co.,Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0